UK BS 8214:2026 & US NFPA 80 Gap Tolerance Checker

Select a standard, tap a frame edge, and verify generic perimeter and threshold tolerances—including FD30S drop seals and NFPA 80 Steel vs Wood rules.

Interactive door-frame gap tolerance calculator

Instant Pass / Fail Tolerance Guide Matches ClearGap iOS & Android gap evaluation rules
FD-01 HEAD HINGE LOCK THRESHOLD
UK Door Rating Type (BS 8214:2026)
Measured Gap — Head (mm)
mm
WITHIN TOLERANCE Head: 3 mm

Current Door Edge Readings
Primary Fire-Test Evidence Precedence: Where manufacturer primary fire-test evidence, a global assessment, third-party certification (BM TRADA Q-Mark, Certifire, FIRAS, UL, Intertek), or local Authority Having Jurisdiction (AHJ) approval specifies tolerances differing from generic defaults, the primary test evidence governs. This reference tool does not certify statutory compliance.

Plug Reference & Rules

BM TRADA Q-Mark plugs & statutory quick summaries

BM TRADA Q-Mark Outer Plug Colour

Indicates fire-resistance rating on certified UK timber fire door leaves.

Yellow · FD30 Blue · FD60 Brown · FD90 Black · FD120

BM TRADA Inner Tree Colour

Indicates certification scope supplied by the manufacturer or processor.

Silver · Complete Doorset Green · Leaf w/ Intumescents Red · Leaf w/o Intumescents Orange · Factory Glazing

UK BS 8214:2026 Quick Rules

Covers timber, metal, and composite doors: generic perimeter head, hinge, lock, and meeting stiles are 2–4 mm (nominal 3 mm). Under 2 mm flags a binding advisory.

Read BS 8214:2026 Guide → What Changed in 2026 →

US / Canada NFPA 80 Quick Rules

Measured on the pull side: Steel & 20-min Wood in HM frames allow 1/16"–3/16"; Wood rated >20-min is capped at ≤1/8" max.

Read full NFPA 80 Guide →

Try the Sample Building free — 25 doors and the gap checker included.

No account. Works offline in every stairwell on iOS and Android.