UK BS 8214:2026 & US NFPA 80 Gap Tolerance Checker
Select a standard, tap a frame edge, and verify generic perimeter and threshold tolerances—including FD30S drop seals and NFPA 80 Steel vs Wood rules.
Interactive door-frame gap tolerance calculator
UK Door Rating Type (BS 8214:2026)
Measured Gap — Head (mm)
mm
WITHIN TOLERANCE
Head: 3 mm
Current Door Edge Readings
Primary Fire-Test Evidence Precedence: Where manufacturer primary fire-test evidence, a global assessment, third-party certification (BM TRADA Q-Mark, Certifire, FIRAS, UL, Intertek), or local Authority Having Jurisdiction (AHJ) approval specifies tolerances differing from generic defaults, the primary test evidence governs. This reference tool does not certify statutory compliance.
Plug Reference & Rules
BM TRADA Q-Mark plugs & statutory quick summaries
BM TRADA Q-Mark Outer Plug Colour
Indicates fire-resistance rating on certified UK timber fire door leaves.
Yellow · FD30
Blue · FD60
Brown · FD90
Black · FD120
BM TRADA Inner Tree Colour
Indicates certification scope supplied by the manufacturer or processor.
Silver · Complete Doorset
Green · Leaf w/ Intumescents
Red · Leaf w/o Intumescents
Orange · Factory Glazing
UK BS 8214:2026 Quick Rules
Covers timber, metal, and composite doors: generic perimeter head, hinge, lock, and meeting stiles are 2–4 mm (nominal 3 mm). Under 2 mm flags a binding advisory.
US / Canada NFPA 80 Quick Rules
Measured on the pull side: Steel & 20-min Wood in HM frames allow 1/16"–3/16"; Wood rated >20-min is capped at ≤1/8" max.
Read full NFPA 80 Guide →Try the Sample Building free — 25 doors and the gap checker included.
No account. Works offline in every stairwell on iOS and Android.